Showing 12 vulnerabilities on this page for Pelco Sarix Professional

Signals CISA KEV Ransomware Nuclei
Schneider Electric SE vulnerability results
VulnerabilityTitle and contextCVSSEPSSPoCsSignalsSTIX action

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.

CWE-295Mar 9, 2018
CVSS7.5v3.1EPSS0.962%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.

CWE-287Mar 9, 2018
CVSS8.1v3.1EPSS1.34%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.

CWE-120Mar 9, 2018
CVSS9.8v3.1EPSS2.79%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'.

CWE-20Mar 9, 2018
CVSS9.8v3.1EPSS2.06%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'

CWE-20Mar 9, 2018
CVSS9.1v3.1EPSS1.73%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.

CWE-20Mar 9, 2018
CVSS9.8v3.1EPSS2.06%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

CWE-798Mar 9, 2018
CVSS9.8v3.1EPSS2.2%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'

CWE-20Mar 9, 2018
CVSS7.5v3.1EPSS1.64%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges.

CWE-287Mar 9, 2018
CVSS9.8v3.1EPSS2.2%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67.

CWE-611Mar 9, 2018
CVSS8.8v3.1EPSS1.59%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker.

CWE-287Mar 9, 2018
CVSS5.3v3.1EPSS1.21%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'.

CWE-20Mar 9, 2018
CVSS9.8v3.1EPSS2.06%PoCs0SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templatesSTIX