Schneider Electric SE Vulnerabilities and Affected Products
Vulnerabilities associated with Pelco Sarix Professional.
Products
Clear product- U.Motion20 vulnerabilities
- Pelco Sarix Professional12 vulnerabilities
- Embedded Web Servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR02008 vulnerabilities
- 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS4 vulnerabilities
- Citect Anywhere4 vulnerabilities
- IIoT Monitor 3.1.384 vulnerabilities
- Modicon M221, all references, all versions prior to firmware V1.6.2.04 vulnerabilities
- Modicon M5804 vulnerabilities
- PowerSCADA Anywhere4 vulnerabilities
- U.motion Builder4 vulnerabilities
- Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)3 vulnerabilities
- EVLink Parking v3.2.0-12_v1 and earlier3 vulnerabilities
- Modicon M3403 vulnerabilities
- Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions)3 vulnerabilities
- Modicon Quantum3 vulnerabilities
- Pelco Sarix Professional V13 vulnerabilities
- Pelco VideoXpert Enterprise3 vulnerabilities
- Ampla MES2 vulnerabilities
- BMXNOR0200H Ethernet / Serial RTU module2 vulnerabilities
- ClearSCADA2 vulnerabilities
- Modicon Premium2 vulnerabilities
- Modicon Premium, Modicon Quantum, Modicon M340, BMXNOR02002 vulnerabilities
- SoMachine HVAC Programming Software2 vulnerabilities
- U.motion Server2 vulnerabilities
- Wiser for KNX2 vulnerabilities
| Vulnerability | Title and context | CVSS | EPSS | PoCs | Signals | STIX action |
|---|---|---|---|---|---|---|
CVE-2018-7234HIGH | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate. CWE-295Mar 9, 2018 | CVSS7.5v3.1 | EPSS0.962% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7236HIGH | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service. CWE-287Mar 9, 2018 | CVSS8.1v3.1 | EPSS1.34% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7238CRITICAL | A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code. CWE-120Mar 9, 2018 | CVSS9.8v3.1 | EPSS2.79% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7232CRITICAL | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'network.ieee8021x.delete_certs'. CWE-20Mar 9, 2018 | CVSS9.8v3.1 | EPSS2.06% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7237CRITICAL | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file' CWE-20Mar 9, 2018 | CVSS9.1v3.1 | EPSS1.73% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7231CRITICAL | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'. CWE-20Mar 9, 2018 | CVSS9.8v3.1 | EPSS2.06% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7229CRITICAL | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials. CWE-798Mar 9, 2018 | CVSS9.8v3.1 | EPSS2.2% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7235HIGH | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file' CWE-20Mar 9, 2018 | CVSS7.5v3.1 | EPSS1.64% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7228CRITICAL | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and get the administrator privileges. CWE-287Mar 9, 2018 | CVSS9.8v3.1 | EPSS2.2% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7230HIGH | A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67. CWE-611Mar 9, 2018 | CVSS8.8v3.1 | EPSS1.59% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7227MEDIUM | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieving of specially crafted URLs without authentication that can reveal sensitive information to an attacker. CWE-287Mar 9, 2018 | CVSS5.3v3.1 | EPSS1.21% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |
CVE-2018-7233CRITICAL | A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'model_name' or 'mac_address'. CWE-20Mar 9, 2018 | CVSS9.8v3.1 | EPSS2.06% | PoCs0 | SignalsNot listed in CISA KEVNo known ransomware useNo Nuclei templates | STIX |